Positioning kits for doypacks, pouches and soft flasks

The positioning kits for doypacks, pouches and soft flasks help maintaining the logger sensor at the cold point inside the process. Depending on the applications, the logger will be placed inside or outside the container.

The following examples are usual devices, but customization can be studied upon request.


Doypacks – extendible bottom – logger inside


For​ PicoVACQ with thread.


The H frame positioning kit includes an H frame structure with nuts and wing nuts. At the center of the frame, a thread maintains the logger. It is used across the wall.

  • Fix the H frame on the bottom of the doypack from the outside, after having made 4 holes in the bottom with an awl.
  • Maintain the device with the wing nuts.
  • Pierce the bottom of the doypack and insert the thread of the H frame.
  • Scew the logger on the thread from inside the doypack.
TMI-Orion positioning kit for data logger in doypack-bottom frame
TMI-Orion positioning kit for data logger in doypack-bottom frame
TMI-Orion positioning kit for data logger in doypack-bottom frame

Assembly with H frame positioning kit.

Flat doypacks and pouches - logger outside


    For across the wall use:


  • Insert the structure in the doypack or pouch.
  • Place the o-ring on the thermowell.
  • Pierce the wall of the pouch and screw the thermowell in the nut of the frame.
  • Insert the logger probe in the sheath, with or without spacers.
TMI-Orion positioning kit for data logger in soft flask-self-drilling screw-across the cap
TMI-Orion positioning kit for data logger in soft flask-self-drilling screw-across the cap

For​ NanoVACQ Flat Needle, PicoVACQ 1Td and NanoVACQ 1Td with threaded probe.

The Bell shaped positioning kit includes a sheath with a thermowell and a structure that follows the shape and dimensions of the doypack or pouch.

Assembly with Bell shaped positioning kit.

Soft flask with cap - logger outside


For NanoVACQ Flat Needle, PicoVACQ 1T and NanoVACQ 1Td with threaded rod.

The device includes a Self-drilling screw for PicoVACQ and NanoVACQ (TMI0001_01), a silicon joint (TMI00001_04) and an o-ring. It fits on the cap of the soft flask.

  • Pre-pierce the cap with an awl.
  • Place the silicon joint on the cap.
  • Screw and tighten the self-drilling screw.
  • Place an o-ring on the logger, then insert the logger probe in the self-drilling screw.
TMI-Orion positioning kit for data logger-across the cap
TMI-Orion positioning kit for data logger in soft flask-self-drilling screw-across the cap
TMI-Orion positioning kit for data logger in soft flask-self-drilling screw-across the cap

Assemby with a Self-drilling screw for PicoVACQ and NanoVACQ (TMI0001_01), a silicon joint (TMI00001_04) and an o-ring.



| For more information, download the data sheet!

  •  Accessoires - FR
  • Accessories - En