Positioning Kits for jars

The positioning kits for jars help maintaining the logger sensor at the cold point inside the process. Depending on the applications, the logger will be placed inside or outside the container.

The following examples are usual devices, but customization can be studied upon request.  


Metal cap - logger outside the jar


For NanoVACQ Flat Needle, PicoVACQ 1Td and NanoVACQ 1Td with threaded probe
.


The temperature sheath kit (PROBE_PE_T) includes a thermowell, a nut and a watertightness o-ring, it can be completed by one or more metal (LOT_E) or PEEK (ENT_PEEK) spacers.

  • Pierce the cap at its center with a punch.
  • Fit the logger probe in the sheath, with or without spacers.
  • Place the o-ring under the cap and screw the nut.
  • Close the jar.
  • Fit the logger probe in the sheath, with or without spacers.
TMI-Orion positioning kit for data logger in jar-across the wall
TMI-Orion positioning kit for data logger in jar-across the cap
TMI-Orion positioning kit for data logger in jar-across the cap


Assembly with the Temperature sheath kit (PROBE_PE_T) and metal spacer (LOT_E)

Metal cap - logger inside the jar


For PicoVACQ with thread.

The Positioning kit - straight (KIT_TIN_PVQ) includes a double plate with thread and a threaded rod to maintain the logger high up. It is used with high temperature adhesive tape or across the cap.

Across the cap:


  • Pierce the center of the cap with an awl.
  • Place the first plate by inserting its thread through the cap wall.
  • Screw the second plate on the thread of the first.
  • Screw the threaded rod on the plate.
  • Screw the logger on the threaded rod. The logger sensor must be at the cold point.
TMI-Orion positioning kit for data logger in jar-across the wall

Assembly with the Positioning kit - straight (KIT_TIN_PVQ) across the wall.

TMI-Orion positioning kit for data logger in jar-across the wall
TMI-Orion positioning kit for data logger in jar-across the wall


    For use with high temperature adhesive tape (ADHESIF-HT):


  • Glue the plate to the bottom of the jar with a piece of high temperature adhe​sive tape.
  •  Visser la tige filetée sur le plateau.

  • Screw the logger on the threaded rod. The logger sensor must be at the cold point.
TMI-Orion positioning kit for data logger in jar- adhesive tape

Assembly with the Positioning kit - straight (KIT_TIN_PVQ) and high temperature adhesive tape (ADHESIF_HT).

TMI-Orion positioning kit for data logger in jar
TMI-Orion positioning kit for data logger in jar



| For more information, download the data sheet!

  •  Accessoires - FR
  •  Accessories - EN