Hospital sterilization control - Medical Sector

Your Industry >> Hospital sterilization control >>

HOSPITALS - STERILIZATION CENTERS

TMI-Orion offer a range of self-contained data loggers for sterilization control. These data loggers are used by hospital sterilization rooms, validation organizations or manufacturers of sterile products.


Validation of steam sterilization

The ValiVACQ system has been designed for operational qualification. It is made of a set of data loggers (maximum 12) and the ValiVACQ software. The logger models can be different within a given system. This system allows full compliance with the European norm requirements.

A multi-logger interface makes programming and downloading possible up to twelve loggers at the same time.

Interface MO2003 + NanoVACQ 1.JPG
RS 232 multi-logger interface system
with different logger models

 

 


DSC00508.JPG

USB multi-logger interface system
with different logger models

European Norm EN554 - Sterilization of medical devices - Validation and routine checking of steam sterilizers - is the reference standard for operational qualification of steam autoclaves.

The norm demands that :
- Temperature be measured at the core of the load
- Saturated steam be checked at base plate level
- Temperature and pressure be maintained constant while on hold pattern
- Sterilization temperature while on hold pattern be :
- within specified temperature range, the upper control limit being equal to sterilization temperature plus 3°C,
- with no deviation exceeding 1°C,
- and temperature difference of any 2 points inferior to 2°C.
- Temperature be set within 15s in autoclave whose volume is inferior to 800L, and within 30s in more voluminous ones.

ValiVACQ system is TMI-ORION's response to the demand

The loggers can be located at the core of loads. They log temperature and pressure versus time.

UIU Load Placement of NanoVACQ 1Tc 1Pt pic5.jpg
Contrôle du cycle de stérilisation au coeur
d'une charge d'instruments
enregistreur de température stérilisation hospitalière_2
Contrôle du cycle de stérilisation au coeur
d'une charge de linge

Valivacq system performances meets or exceeds the recommendations of the guide of European standard EN554, published by AFNOR (Reference GA S 98130).

  • Temperature accuracy better or equal to 0.17°C - Valivacq: 0.10°C
  • Pressure accuracy better or equal to16mbar - Valivacq: 10 mbar

Furthermore, the Valivacq software makes it possible to publish a report in compliance with norm EN554 requirements. (see ValiVACQ data sheet in "data processing software").


Routine control of steam sterilizers

Thanks to an excellent reliability at elevated temperature, the TMI-Orion data loggers are very suitable to the routine control of the autoclaves specifications during sterilization cycles. The NanoVACQ type 3, or Calivac™ when sold with Sterigest® software is the solution to the requirements of health care centers.


Ethylen Oxide sterilization control top

For ethylen oxide low temperature sterilization process the NanoVACQ-Ex data loggers have temperature and humidity/temperature sensors.

These loggers can be programmed and read out with multi-logger interface. They are designed according the Ex norms (explosion proof).

 

Washing and desinfection temperature control

nvf4.jpg MiniVACQ_pc_main.jpg

NanoVACQ Flat MiniVACQ

 

Two data logger models fit the control of temperature for washing and desinfection processes: NanoVACQ Flat and MiniVACQ. They can easily be placed inside the equipments thanks to their small dimensions.


Customer log in

last software versions
user's guides ......

>


Distributor log in

you can find the last software versions, the user's guides, the price list and other information.
>



Product ranges related to this page :
MiniVACQ temperature data logger
NanoVACQ Temperature Humidity data logger
NanoVACQ Temperature Pressure data logger
NanoVACQ / NanoVACQ Flat / XFlat (temperature)
Data processing software



Homepage  |  About TMI  |  List of products  |  Your Industry  |  News  |  Distribution network  |  Documentation  |  Contact  |