MONITOR, VALIDATE, CONTROL YOUR PROCESSES

TMI-Orion will help you find the best solution for measuring all the physical parameters you are dealing with in your processes:

Steam sterilization, EtO sterilization, Depyrogenation, Freeze drying, Temperature monitoring ...

A data processing software will assist you for a better process quality management in compliance with the norms FDA 21 CFR Part 11.
TEMPERATURE (Pt1000 or thermocouples), PRESSURE, HUMIDITY
TMI-Orion has a solution for each one of those parameters in accordance with the need of each process.
 Multi sensor data loggers with numerous probe combinations give a cost effective advantage for increasing the number of measurement points.
 
 
 Process Physical parameters Recommended TMI-Orion models
Validation of steam sterilizationTemperature and Pressure

PicoVACQ PT, PicoVACQ 1Tc, PicoVACQ 1Td, NanoVACQ 1Tc, NanoVACQ 1,2 or 3Td, NanoVACQ PT-Tc, VACQ xFlat

Routine test of steam sterilizationTemperature and PressureNanoVACQ PT-Tc
Ethylen Oxyde sterilizationTemperature and HumidityNanoVACQ HT Ex
Depyrogenation Temperature PicoVACQ 1Td, VACQ xFlat (with thermal shields)
Freeze DryingTemperatureNanoVACQ 1Tc-2Td, NanoVACQ 1Tc-2Tdi
 Spray Temperature and Pressure PicoVACQ PT
 Freezer mapping Temperature PicoVACQ 1T, NanoVACQ 1T
 Washing, Desinfection Temperature NanoVACQ Flat, MiniVACQ
 Pouches, containers TemperatureNanoVACQ Flat

 

 LIST OF PRODUCTS FOR PHARMACEUTICAL, HEALTH CARE AND BIOTECHNOLOGIES 

Picofamily-2.gif


PicoVACQ Temperature

PicoVACQ Temperature is a series of models offering a wide variety of temperature probes.
The smallest, PicoVACQ 1T, diameter 15 mm and height 22 mm, has an internal probe. 
PicoVACQ 1Tc can be manufactured with different probe sizes, diameter 3 mm and length up to 100 mm.

The PicoVACQ 1Td has a semi-rigid stainless steel probe or a flexible probe, diameter 2 mm, length up to 1000 mm. This model, associated with a thermal shield, is very well appreciated for depyrogenation processes.

A disconnectable probe version is also available, PicoVACQ 1Tdi.

All these models can operate up to 150°C and they are watertight. They can be immersed or used in steam environment. Their dimensions may vary with negative temperature range or with the type of semi-rigid and flexible probes.

data sheet

  

 PVQ PT.gif

PicoVACQ Pressure and Temperature

The PicoVACQ PT is a data logger able to measure pressure and temperature from 0°C to 150°C up to 15 bar.
Its tiny dimensions, diameter 15 mm (16 mm at the top) and length 35 mm, make it very useful for manufacturing processes of small packagings like sprays. It can also be used in any steam sterilization application.

data sheet

  

NVQ1Tc2Tdi-2.gif  NanoVACQ 1Tc-2Tdi


NanoVACQ Temperature

The NanoVACQ Temperature is a series of models which offers a wide variety of probe arrangements.
The simplest, NanoVACQ 1Tc, diameter 31 mm and height 31 mm, can ne manufactured with different probe sizes, diameter 3 mm and length uo to 100 mm. The NanoVACQ 1Td has a semi-rigid stainless steel probe or a flexible probe, diameter 2 mm, length 1000 mm. Two or three probes are also available in various combinations of length and material, NanoVACQ 2Td, NanoVACQ 3Td. 

All these models can operate up to 150°C and they are watertight. They can be immersed or used in steam environment. Their heights may vary with temperature range from 31 mm to 123 mm. They are the ideal data loggers for steam sterilization validation.

The models NanoVACQ 1Tc-2Td and the disconnectable probe version NanoVACQ 1Tc-2Tdi are very well adapted for freeze drying process.

datasheet

  


Nanofamily-2.gif 

NanoVACQ 

 NVQ1Td-1.jpg
NanoVACQ 1Td
 NVQ3Td-1.jpg
NanoVACQ 3Td

 NanoVACQ Flat family1.jpg

The NanoVACQ Flat is a single temperature data logger. The temperature probe can be internal or have various sizes up to 100 mm. Its small size, diameter 40 mm and height 11 mm, makes it suitable for washing processes or any sterilization process.

data sheet 
  
NVQ PT - Tc sonde hybride.gif

NanoVACQ Pressure and Temperature

The NanoVACQ Pressure and Temperature is a series of data loggers able to measure pressure and temperature inside autoclaves. For the most accurate data during transients, the NanoVACQ PT-Tc with a thin hybrid diameter probe is recommended. Associated with some NanoVACQ 1Tc , the group of data loggers constitute a complete validation system. 

Semi-rigid or flexible probes are also available instead of a rigid probe, NanoVACQ PT-Td. 

data sheet

   
NVQ HT.gif


NanoVACQ HT     

 
PVQ Humidité.gif

PicoVACQ HT


NanoVACQ Humidity and Temperature

NanoVACQ HT 80 Ex for Ethylen oxyde sterilization control measures temperature and relative humidity.
Most of the NanoVACQ are available in Ex version.
data sheet

PicoVACQ HT and most of the PicoVACQ are available in Ex version.
data sheet

  
 Min-2.gif

MiniVACQ Temperature

The MiniVACQ is an ideal temperature data logger for the washing-desinfection process.

data sheet

  

VACQ xFlat

The VACQ xFlat are thermocouple data loggers. They can be used for steam sterilization control. In this application the data logger is placed outside the autoclave. They can also be used inside depyrogenation process (dry heat) where the data logger is protected by a thermal shield.

The VACQ XFlat is available in 4, 8 or 16 thermocouples version. Dimension of model 4 thermocouples: 80x104x10 mm 

 VACQXFlat.jpg
  
 2GHz4-1.JPGRadio transmission

All the NanoVACQ models are available with radio transmission (2.4 GHz) and can be used inside autoclaves.
These data loggers are ideal for real time monitoring and process control.
  
Operating software   


QLEVER Pharma
 
compliant with FDA 21 CFR Part 11 

QLEVER Pharma takes you from a detailed programming Setup to a complete measurement report : description of test, description of the equipment, selection of loggers, position of loggers in the equipement, definition of calculations and events...

data sheet

 


xETal Temperature

for temperature calibration 

xETal_Temperature software helps periodically adjusting and calibrating TMI-Orion temperature loggers.
This calibration can be done in th user's metrology laboratory, on site, for better productivity.

data sheet

 

Thermal shields

For any application at a temperature higher
than 150°C it is necessary to protect the
data logger with a thermal shield.

See our proposals

 
 Thermal shield 200/120
MONO-USB-retaillé.jpg  MOUSB interface1.JPG

Communication with the data loggers can be done in various ways:

  • Single USB interface
  • Multi logger USB interface